M12 Power male 0° / female 90° L-cod.

PUR 4x1.5 bk UL/CSA+drag ch. 1.5m

Art.No.: 7000-P4151-P070150
Weight: 0.192 kg
Country of origin:  DE
Model designation:  MSWDLL0-WAL-TP07_1.5

For further Information please Register or Login

Download to the Data Cart Download to Easy-Import-Export

Description

Advantages of our M12 power connectors:

Our M12 power connectors are ideal for supplying power to your industrial applications and are specially optimised for harsh environments.

The L-coded connectors are available in 4- and 5-pin versions and offer a current carrying capacity of 16A per pin at 63V DC. They are ideal for supplying power to decentralised devices such as I/O & fieldbus modules, power supply units, fuses, engines and motors. The Profinet User Organisation (PNO) has also described the L-coding as the future standard for the low-voltage supply of automation components, which ensures compatibility across different systems.

All Murrelektronik connectors are 100% tested during the manufacturing process to ensure the highest quality and reliability. The contacts are gold-plated, which ensures excellent conductivity. Thanks to the high IP67 protection rating and the integrated protective conduit connection, they are ideal for demanding industrial environments. They are also vibration-resistant - this is guaranteed by the integrated vibration protection.

The M12 power connectors are designed in accordance with the IEC 61076-2-111 standard and UL-approved in accordance with 2237 (PVVA - E492831). Our connectors are resistant to oils and cooling lubricants. However, resistance to aggressive media should be tested for each specific application.

Different cable lengths are possible on request. Are you missing technical information? Feel free to use our technical dictionary, where you will find explanations of coding and other technical details.

Product details:
Power
M12 – M12, 4-pole
Male straight
Female 90°
L-coded
with cable sleeves
Plastic housings with good resistance against chemicals and oils.
The resistance to aggressive media should be individually tested for your application. Further details on request.
Further cable lengths on request.
CE
China RoHS 50
UL Power
cURus
UKCA

Header
Material short text MSWDLL0-WAL-TP07_1.5
Cable length 1,50 m
Side 1
Family construction form M12P
No. of poles 4
Coding L
Gender male
Mounting method inserted, screwed
Threaded hole M12 x 1
Tightening torque 0,6 Nm
Width across flats SW17
Cable outlet straight
suitable for corrugated tube (internal Ø) 12 mm
Material PUR
Material contact Copper alloy
Coating contact gold plated
Degree of protection (EN IEC 60529) IP65, IP67, IP69K
Side 2
Family construction form M12P
No. of poles 4
Coding L
Gender female
Mounting method inserted, screwed
Threaded hole M12 x 1
Tightening torque 0,6 Nm
Width across flats SW17
Cable outlet angled
suitable for corrugated tube (internal Ø) 16,4 mm
Material PUR
Material contact Copper alloy
Coating contact gold plated
Degree of protection (EN IEC 60529) IP65, IP67, IP69K
Electrical data | Supply
Operating voltage DC max. 63 V
Current operating per contact max. 12 A
Diagnostics
Status indication LED No
Installation | Connection
Width across flats SW17
Device protection | Electrical
Degree of protection (EN IEC 60529) IP67, IP65, IP69K
Additional condition protection degree inserted, screwed
Pollution Degree 3
Rated surge voltage 1,5 kV
Material group (IEC 60664-1) I
Mechanical data | Material data
Material housing PUR
Material screw connection Brass
Coating of fitting nickel plated
Material gasket FKM
Mechanical data | Mounting data
Mounting method inserted, screwed, Shaking protection
Environmental characteristics | Climatic
Operating temperature min. -30 °C
Operating temperature max. 85 °C
Additional condition temperature range depending on cable quality
Important installation notes
Note on bending radius Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Note on strain relief Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Conformity
Product standard EN IEC 61076-2-111

General data | Cable
Cable identification P07
Cable Type 3
Function cable Power
Structure | Cable
Amount stranding 1
Stranding 4 wires stranded
Mechanical data | Cable
Cable weigth 90,96 g/m
Material wire insulation PP
Amount wires 4
Outer diameter insulation 2,3 mm
Outer diameter tolerance core insulation ± 0,1 mm
Shore hardness wire insulation 60 ± 5 Shore D
Ingredient freeness wire insulation lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
Printing color of wire insulation white (isolation blue), white (isolation brown), white (isolation black), black (white isolation)
Amount strands (wire) 84
Diameter of single wires 0,15 mm
Conductor crosssection (wire) 1,5 mm²
Material conductor wire Stranded copper wire, bare
Conductor type (wire) strand class 6
Outer-diameter (jacket) 7,2 mm
Tolerance outer diameter (sheath) ± 5 %
Material jacket PUR
Shore hardness jacket 90 ± 5 Shore A
Freedom from ingredients (jacket) lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
Material property (jacket) abrasion-resistant, low adhesion, good machinability, matte
Electrical data | Cable
Conductor resistance (wire) 13.3 Ω/km @ 20 °C
Nominal voltage max. 1.000 V
Withstand voltage (wire - wire) 10 kV @ 60 s
Withstand voltage (wire - jacket) 10 kV @ 60 s
Current load capacity (standard) to DIN VDE 0298-4
Current load capacity max. (wire) 14,4 A
Temperature range | Cable
Operating temperature min. (static) -50 °C
Operating temperature max. (static) 80 °C / 90 °C @ 10000 h Operation
Operating temperature min. (dynamic) -25 °C
Operating temperature max. (dynamic) 80 °C / 90 °C @ 10000 h Operation
Resistances | Cable
Flame resistance IEC 60332-1-2, IEC 60332-2-2, UL 1581 § 1080, CSA FT2
Oil resistance IEC 60811-404
Chemical resistance good
Other resistances good resistance to gasoline, resistant to hydrolysis, resistant to microbes
Installation | Cable
Bending radius (fixed) 5 × Outer diameter
Bending radius (dynamic) 10 × Outer diameter
No. of bending cycles (C-track) 5 Mio. @ 25 °C
Traversing distance (C-track) 5 m @ 25 °C
Travel speed (C-track) 3.3 m/s @ 25 °C
Acceleration (C-track) 5 m/s² @ 25 °C
No. of torsion cycles 5 Mio.
Torsion stress ± 180 °/m
Torsion speed 35 cycles/min

URL Webshop https://shop.murrelektronik.com/7000-P4151-P070150
GTIN 4048879781787
ECLASS-6.0 27279218
ECLASS-6.1 27279218
ECLASS-7.0 27279218
ECLASS-7.1 27279218
ECLASS-8.0 27279218
ECLASS-8.1 27279218
ECLASS-9.0 27060327
ECLASS-9.1 27060311
ECLASS-10.0.1 27060311
ECLASS-10.1 27060311
ECLASS-11.0 27060311
ECLASS-11.1 27060311
ECLASS-12.0 27060327
ECLASS-13.0 27060311
ECLASS-14.0 27060311
ETIM-5.0 EC001855
ETIM-6.0 EC001855
ETIM-7.0 EC001855
ETIM-8.0 EC001855
customs tariff number 85444290
EAN 4048879781787
Packaging unit 1
customs tariff number 85444290
EAN 4048879781787
Packaging unit 1

 
Data Regarding Article:
  • Product-PDF
  • Approval: UL Listed CA E492831-PVVA7_ulc_z_c.pdf (C)
  • Approval: UL Listed US E492831-PVVA_ul_z_c.pdf (C)
  • Construction files: STP 7000-P4151-P07_stp_x_a.zip (A)
  • Document: Installation Guide inr01_zir_en_01.pdf (01)

    English

    • English
    • Deutsch
  • Information: Certificate of conformity Murrelektronik GmbH 19-08-25_(1) RoHS REACh exemption 6c_DoC_z_a.pdf (04)
  • Information: Certificate of conformity Murrelektronik GmbH 14-08-25_(6) California Prop65 Ni surface_DoC_z_a.pdf (01)
  • Information: Certificate of conformity Murrelektronik GmbH 18-08-25_(5) China RoHS 2 50EEP_DoC_z_a.pdf (01)