Online shop questions? Pls. send the email to shop@murrelektronik.com.cn

DRIVE CLIQ CABLE

Specification: 6FX8002-2DC10-1BH5

Art.No.: 7000-SS051-8801750
Weight: 1.175 kg
Country of origin:  DE
Model designation:  M6FX8002-2DC10-1BH5

For further Information please Register or Login

Download to the Data Cart Download to Easy-Import-Export

Description


Advantages of our connectors:

Our connectors are versatile and specially optimised for industrial environments. All connectors are 100% tested during the manufacturing process to ensure the highest quality and reliability.

The contacts are gold-plated, which ensures optimum conductivity. Thanks to the high degree of protection, the connectors are ideal for demanding industrial environments. They are also vibration-resistant - this is ensured by the union nut with vibration protection.

Our connectors are resistant to oils and cooling lubricants, but resistance to aggressive media should be tested for each specific application. Different cable lengths available on request

If you are missing technical information? Please feel free to use our dictionary to find more technical details.

Product details:
DRIVE-CLiQ signal cable for SINAMICS S120 and motors with DC 24 V wires
Male straight – male straight
DRIVE-CLiQ IP67 – DRIVE CLiQ IP20
Further cable lengths on request.
The resistance to aggressive media should be individually tested for your application. Further details on request.

Cable length 17,5 m
Side 1
Mounting method pluggable
Family construction form RJ45
Side 2
Mounting method pluggable
Electrical data | Supply
Operating voltage AC max. 30 V
Operating voltage DC max. 30 V
Operating current max. 1,76 A
Device protection | Electrical
Degree of protection (EN IEC 60529) IP20, IP67
Pollution Degree 3
Rated surge voltage 0,5 kV
Material group (IEC 60664-1) II
Mechanical data | Mounting data
Looking techniques DRIVE-CLiQ
Environmental characteristics | Climatic
Operating temperature min. -20 °C
Operating temperature max. 80 °C
Additional condition temperature range depending on cable quality
Important installation notes
Note on strain relief Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Note on bending radius Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.

Cable
wire arrangement (green, yellow), (pink, blue), (red, black)
General data | Cable
Cable identification 880
Jacket Color green
Type of Certificate cURus
Structure | Cable
Amount stranding 3
Stranding 2 wires with 2 Filler twisted
Amount stranding (type 2) 1
Stranding (type 2) 3 Stranded joints with Filler twisted
Cable shielding (type) copper braid, tinned
Cable shielding (coverage) 85 %
Banding Fleece, Foil
Filler yes
wire arrangement (green, yellow), (pink, blue), (red, black)
Mechanical data | Cable
Cable weigth 75,9 g/m
Material jacket PUR
Freedom from ingredients (jacket) lead-free, CFC-free, halogen-free
Outer-diameter (jacket) 7 mm
Tolerance outer diameter (sheath) ± 5 %
Material wire insulation Polyolefin
Amount wires 4
Outer diameter insulation 1 mm
Outer diameter tolerance core insulation ± 5 %
Amount strands (wire) 19
Diameter of single wires 0,118 mm
Conductor crosssection (wire) 0,2 mm²
Material conductor wire Stranded copper wire, bare
Conductor type (wire) strand class 6
Material wire insulation (Data) Polyolefin
Outer diameter wire insulation (Data) 1 mm
Tolerance outer diameter wire insulation (data) ± 5 %
Amount wires (Data) 2
Amount strands wire (Data) 19
Diameter of single wires (Data) 0,16 mm
Conductor crosssection wire (Data) 0,38 mm²
Material conductor wire (Data) copper stranded wire, tinned
Wire conductor type (Data) strand class 6
Electrical data | Cable
Nominal voltage AC max. 30 V
Current load capacity (standard) to DIN VDE 0298-4
Current load capacity min. wire 2,4 A
Current load capacity min. Wire (Data) 6 A
Characteristic impedance 100 Ω ± 5 % @ 100 MHz
Electrical resistance line constant wire 94 Ω/km @ 20 °C
Electrical resistance coating wire (Data) 55 Ω/km @ 20 °C
Isolation resistance 1000 MΩ × km
Temperature range | Cable
Min. operating temperature (static) -20 °C
Max. operating temperature (fixed) 80 °C
Operating temperature min. (dynamic) -20 °C
Operating temperature max. (dynamic) 60 °C
Resistances | Cable
Flame resistance UL 1581 § 1090 | UL 1581 § 1100 FT2 | IEC 60332-2-2
chemical resistance Good, application-related testing
Gasoline resistance Good, application-related testing
Oil resistance Good, application-related testing | DIN EN 60811-404
Installation | Cable
Bending radius (dynamic) 10 x Outer diameter
No. of bending cycles (C-track) 5 Mio.
Traversing distance (C-track) 50 m @ 25 °C | horizontal
Travel speed (C-track) 5 m/s @ 25 °C
Torsion stress ± 30 °/m

ECLASS-6.0 27061801
ECLASS-7.0 27061801
ECLASS-8.0 27061801
ECLASS-9.0 27061801
ECLASS-10.1 27060307
ECLASS-11.1 27060307
ECLASS-12.0 27060307
ETIM-5.0 EC000830
customs tariff number 85444210
EAN 4048879541107
Packaging unit 1

 
Data Regarding Article:
  • Product-PDF
  • Information: Certificate of conformity Murrelektronik GmbH 17-12-23_(1) RoHS REACh exception 6c_DoC_z_a.pdf (04)
  • Information: Certificate of conformity Murrelektronik GmbH 23-12-23_(1) California Prop65 No Warning_DoC_z_a.pdf (01)