Online shop questions? Pls. send the email to shop@murrelektronik.com.cn

M12 fem. recept. X-cod. / RJ45 male 0° shielded

TPE 4x2x26AWG SF/UTP CAT6a bu UL/CSA. CMR 5m

Art.No.: 7700-51551-S4X0500
Weight: 0.36 kg
Country of origin:  DE
Model designation:  MSXBFH-RA-08D_S4X_5.0-ZS

For further Information please Register or Login

Download to the Data Cart Download to Easy-Import-Export

Description


USA
Transmission properties with channel transmission up to 50 m
Ethernet CAT6A
Flange female straight – male straight
RJ45 – M12, 8-pole
X-coded
shielded
Rear mounting
without cable sleeves
Protection cap
Certificate
Certificate
Certificate
Certificate
Bus technologies
Bus technologies

Cable length 5 m
Side 1
Tightening torque 0,6 Nm
Mounting method inserted, screwed
Family construction form M12
Thread M12 x 1
Gender female
Cable outlet straight
Coding X
No. of poles 8
Width across flats SW17
Degree of protection (EN IEC 60529) IP67
Side 2
Mounting method inserted
Family construction form RJ45
Gender male
Cable outlet straight
Coding X
No. of poles 8
Degree of protection (EN IEC 60529) IP20
Electrical data | Supply
Operating voltage DC max. 60 V
Operating voltage DC (UL-listed) 30 V
Operating current max. 0,5 A
Industrial communication
Transfer parameters CAT6, Class EA (ISO/IEC 11801:2002), (EN 50173-1)
Data transmission rate max. 10 GBit/s
Diagnostics
Status indication LED no
Installation | Connection
Mounting set M16 x 1.5
Installation | Pin assignment
Configuration fully used
Device protection | Electrical
Additional condition protection degree inserted, screwed
Pollution Degree 3
Rated surge voltage 0,8 kV
Material group (IEC 60664-1) I
Mechanical data
Contour for corrugated hose without
Mechanical data | Material data
Coating of fitting nickel plated
Color contact carrier green
Environmental characteristics | Climatic
Operating temperature min. -25 °C
Operating temperature max. 85 °C
Additional condition temperature range depending on cable quality
Important installation notes
Note on strain relief Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Note on bending radius Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.

Cable
wire arrangement (orange-white, orange), (blue-white, blue), (brown-white, brown), (green-white, green)
General data | Cable
Cable identification S4X
Function cable Data
Jacket Color blue
Type of Certificate cURus
Structure | Cable
Amount stranding 4
Stranding 2 wires twisted
Amount stranding (type 2) 1
Stranding (type 2) 4 Stranded joints around Insulation element twisted
Banding Foil
Filler Insulation element
wire arrangement (orange-white, orange), (blue-white, blue), (brown-white, brown), (green-white, green)
Mechanical data | Cable
Cable length max. 66 m
Cable weigth 65,48 g/m
Material jacket TPE
Freedom from ingredients (jacket) lead-free, CFC-free
Outer-diameter (jacket) 7,4 mm
Tolerance outer diameter (sheath) ± 5 %
Material wire insulation HDPE
Amount wires 8
Outer diameter insulation 0,9 mm
Outer diameter tolerance core insulation ± 5 %
Ingredient freeness wire insulation lead-free, CFC-free
Amount strands (wire) 7
Diameter of single wires 26 AWG
Conductor crosssection (wire) 26 AWG
Material conductor wire copper stranded wire, tinned
Electrical data | Cable
Nominal voltage AC max. 600 V
Current load capacity (standard) to DIN VDE 0298-4
Current load capacity min. wire 2 A
Characteristic impedance 100 Ω @ 100 MHz
Electrical resistance line constant wire 212 Ω/km @ 20 °C
AC withstand voltage (wire - wire) 1,5 kV @ 2 s
Electrical capacity line constant (wire - wire) 84850 pF/km
Power frequency withstand voltage (wire - jacket) 1,5 kV @ 2 s
Loop resistance 424 Ω/km
Temperature range | Cable
Min. operating temperature (static) -40 °C
Max. operating temperature (fixed) 80 °C
Operating temperature min. (dynamic) -40 °C
Operating temperature max. (dynamic) 80 °C
Storage temperature min. -40 °C
Storage temperature max. 80 °C
Resistances | Cable
Flame resistance IEC 60332-2-2 | UL 1581 § 1100 FT2 | UL 1581 § 1090
chemical resistance Good, application-related testing
Gasoline resistance Good, application-related testing
Oil resistance DIN EN 60811-404 | Good, application-related testing
Installation | Cable
Bending radius (fixed) 4 x Outer diameter
Bending radius (dynamic) 4 x Outer diameter
No. of bending cycles (C-track) 35 Mio. @ 25 °C
Traversing distance (C-track) 0,6 m @ 25 °C
Travel speed (C-track) 1,2 m/s @ 25 °C
No. of torsion cycles 3 Mio. 25 °C
Torsion stress ± 270 °/m @ 25 °C
Torsion speed 60 cycles/min 25 °C

ECLASS-6.0 27279221
ECLASS-6.1 27279220
ECLASS-7.0 27440103
ECLASS-8.0 27440103
ECLASS-9.0 27440103
ECLASS-10.1 27440103
ECLASS-11.1 27440103
ECLASS-12.0 27440103
ETIM-5.0 EC002599
customs tariff number 85444290
customs tariff number 85444290
EAN 4048879718660
EAN 4048879718660
Packaging unit 1
Packaging unit 1

 
Data Regarding Article:
  • Product-PDF
  • Approval: UL Listed CA E362618-DUXR7_ulc_z_c.pdf (C)
  • Approval: UL Listed US E362618-DUXR_ul_z_c.pdf (C)
  • Construction files: STP 7700-51551_stp_x_a.zip (A)
  • Information: Certificate of conformity Murrelektronik GmbH 17-12-23_(1) RoHS REACh exception 6c_DoC_z_a.pdf (04)
  • Information: Certificate of conformity Murrelektronik GmbH 22-12-23_(6) California Prop65 Ni surface_DoC_z_a.pdf (01)
  • Information: Certificate of conformity Murrelektronik GmbH 13-12-23_(5) China RoHS 2 50EEP_DoC_z_a.pdf (01)
  • Information: Certificate of conformity Murrelektronik GmbH 06-06-25_(10) REACH SVHC CAS No 115-86-6_DoC_z_a.pdf (01)
  • Information: Certificate of conformity UKCA con_01-10.21_uk_z_c.pdf (C)
  • Information: EU declaration of conformity con_01-10.21_ce_z_c.pdf (C)