Family construction form M12
No. of poles 4
Coding D
Gender male
Mounting method inserted, screwed
Thread M12 x 1
Tightening torque 0.6 Nm
Width across flats SW13
Cable outlet straight
Material PUR
Material contact Copper alloy
Coating contact gold plated
Degree of protection (EN IEC 60529) IP67, IP66K, IP65
Side 2
Family construction form M12
No. of poles 4
Coding D
Gender female
Mounting method inserted, screwed
Thread M12 x 1
Tightening torque 0.6 Nm
Width across flats SW13
Cable outlet straight
Material PUR
Material contact Copper alloy
Coating contact gold plated
Degree of protection (EN IEC 60529) IP67, IP66K, IP65
Electrical data | Supply
Operating voltage DC max. 60 V
Current operating per contact max. 1.5 A
Industrial communication
Data transmission rate max. 100 MBit/s
Transfer parameters CAT5, Class D (ISO/IEC 11801:2002), (EN 50173-1)
Industrial communication | Ethernet functionality
duplex Full duplex
Device protection | Electrical
Degree of protection (EN IEC 60529) IP67, IP66K, IP65
Additional condition protection degree inserted, screwed
Pollution Degree 3
Rated surge voltage 1.5 kV
Material group (IEC 60664-1) I
Mechanical data
Contour for corrugated hose without
Mechanical data | Material data
Material screw connection Zinc die-casting
Coating of fitting nickel plated
Environmental characteristics | Climatic
Operating temperature min. -30 °C
Operating temperature max. 85 °C
Additional condition temperature range depending on cable quality
Important installation notes
Note on bending radius Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Note on strain relief Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Conformity
Product standard DIN EN 61076-2-101 (M12)

General data | Cable
Function cable Data
Structure | Cable
Amount stranding 1
Stranding Wires
Cable shielding (type) copper braid, tinned
Cable shielding (coverage) 85 %
Banding Foil
Filler yes
Wire arrangement orange, white, yellow, blue
Mechanical data | Cable
Cable weigth 73.7 g/m
Material wire insulation PE
Amount wires 4
Outer diameter insulation 1.53 mm
Outer diameter tolerance core insulation ± 0.05 mm
Shore hardness wire insulation 55
Ingredient freeness wire insulation CFC-free, halogen-free, lead-free
Amount strands (wire) 7
Diameter of single wires 30 AWG
Conductor crosssection (wire) 22 AWG
Material conductor wire Stranded copper wire, bare
Outer-diameter (jacket) 6.6 mm
Tolerance outer diameter (sheath) ± 5 %
Material jacket PVC
Shore hardness jacket 85
Freedom from ingredients (jacket) CFC-free, lead-free
Material inner jacket FRNC
Color (inner jacket) natural
Electrical data | Cable
Electrical resistance line constant wire 55 Ω/km @ 20 °C
Electrical capacity line constant (wire - wire) 55,000 pF/km
Isolation resistance 2,000 MΩ × km
Nominal voltage AC max. 60 V
Loop resistance 124 Ω/km
AC withstand voltage (wire - wire) 1 kV @ 60 s
Power frequency withstand voltage (wire - jacket) 1 kV @ 60 s
AC withstand voltage (wire - shield) 1 kV @ 60 s
Current load capacity (standard) to DIN VDE 0298-4
Current load capacity min. wire 4.8 A
Characteristic impedance 100 Ω 15 %
Temperature range | Cable
Min. operating temperature (static) -30 °C
Max. operating temperature (fixed) 80 °C
Operating temperature min. (dynamic) -10 °C
Operating temperature max. (dynamic) 70 °C
Installation | Cable
Bending radius (fixed) 5 × Outer diameter
Bending radius (dynamic) 15 × Outer diameter
No. of bending cycles (C-track) 2 Mio. @ 25 °C
Traversing distance (C-track) 5 m @ 25 °C
Travel speed (C-track) 3.3 m/s @ 25 °C
Acceleration (C-track) 2 m/s² @ 25 °C

URL Webshop https://shop.murrelektronik.com/7000-44571-8000200
GTIN 4048879751360
ECLASS-6.0 27061801
ECLASS-6.1 27060307
ECLASS-7.0 27060307
ECLASS-7.1 27060307
ECLASS-8.0 27060307
ECLASS-8.1 27060307
ECLASS-9.0 27060307
ECLASS-9.1 27060307
ECLASS-10.0.1 27060307
ECLASS-10.1 27060307
ECLASS-11.0 27060307
ECLASS-11.1 27060307
ECLASS-12.0 27060307
ECLASS-13.0 27060307
ECLASS-14.0 27060307
ETIM-5.0 EC002599
ETIM-6.0 EC002599
ETIM-7.0 EC002599
ETIM-8.0 EC002599
EAN 4048879751360

 
Data Regarding Article:
  • Product-PDF
  • Approval: CSA CA 080128-0-000_csa_z_c.pdf (C)
  • Approval: CSA US 080128-0-000_csau_z_c.pdf (C)
  • Construction files: STP 7000-44571_stp_x_a.zip (A)
  • Document: ATEX 7000-18001_atx_2_l.pdf (L)
  • Information: Certificate of conformity Murrelektronik GmbH 21-12-23_(5) RoHS REACh no exception_DoC_z_a.pdf (02)
  • Information: Certificate of conformity Murrelektronik GmbH 10-12-23_(1) China RoHS 2 e_DoC_z_a.pdf (01)
  • Information: Certificate of conformity Murrelektronik GmbH 22-12-23_(6) California Prop65 Ni surface_DoC_z_a.pdf (01)
  • Information: EU declaration of conformity 7000-14541_09-10.19_ce_z_d.pdf (D)