M12 male 0° A-cod. / MSUD valve plug A-18mm
PUR 3x0.75 ye UL/CSA+drag ch. 0.3m
Art.No.: | 7000-40881-0360030 |
Alternative product: | |
Weight: | 0.065 kg |
Country of origin: | CZ |
Model designation: | MSKL3-A-W036_0.3 |
Technical Data
Side 1
Family construction form | M12 |
---|---|
No. of poles | 3 |
Coding | A |
Mounting method | inserted, screwed |
Thread | M12 x 1 |
Tightening torque | 0.6 Nm |
Width across flats | SW13 |
suitable for corrugated tube (internal Ø) | 10 mm |
Material | PUR |
Degree of protection (EN IEC 60529) | IP67 |
Side 2
Family construction form | MSUD A |
---|---|
No. of poles | 4 |
Thread | M3 |
Tightening torque | 0.4 Nm |
Material | PBT |
Degree of protection (EN IEC 60529) | IP67 |
Electrical data
Drop-out delay time max. | 20 ms |
---|
Electrical data | Supply
Operating voltage AC | 24 V |
---|---|
Operating voltage AC min. | 19.2 V |
Operating voltage AC max. | 28.8 V |
Operating voltage DC | 24 V |
Operating voltage DC min. | 18 V |
Operating voltage DC max. | 30 V |
Current operating per contact max. | 4 A |
Cut-off peak voltage max. | 55 V |
Current consumption max. | 15 mA |
Diagnostics
Status indication LED | yellow |
---|
Device protection | Electrical
Degree of protection (EN IEC 60529) | IP67 |
---|---|
Additional condition protection degree | inserted, screwed |
Pollution Degree | 3 |
Additional suppressor | Z-Diode |
Rated surge voltage | 0.8 kV |
Material group (IEC 60664-1) | I |
Mechanical data | Material data
Material housing | Plastic |
---|---|
Color housing | black |
Locking material | Zinc die-casting |
Coating locking | Nickeled |
Material gasket | PUR |
Mechanical data | Mounting data
Mounting method | inserted, screwed |
---|
Environmental characteristics | Climatic
Operating temperature min. | -25 °C |
---|---|
Operating temperature max. | 85 °C |
Additional condition temperature range | depending on cable quality |
Important installation notes
Note on bending radius | Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces. |
---|---|
Note on strain relief | Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties. |
Conformity
Product standard | DIN EN 61076-2-101 (M12), DIN EN 175301-803 |
---|
Cable data
General data | Cable
Cable identification | 036 |
---|---|
Cable Type | 3 |
Structure | Cable
Amount stranding | 1 |
---|---|
Stranding | Wires |
Wire arrangement | black 1, black 2, green-yellow |
Mechanical data | Cable
Cable weigth | 56.1 g/m |
---|---|
Material wire insulation | PP |
Amount wires | 3 |
Outer diameter insulation | 1.85 mm |
Outer diameter tolerance core insulation | ± 0.1 mm |
Shore hardness wire insulation | 70 |
Ingredient freeness wire insulation | CFC-free, cadmium-free, silicone-free, halogen-free, lead-free |
Printing color of wire insulation | white (isolation black) |
Amount strands (wire) | 42 |
Diameter of single wires | 0.15 mm |
Conductor crosssection (wire) | 0.75 mm² |
Material conductor wire | Stranded copper wire, bare |
Conductor type (wire) | strand class 6 |
Outer-diameter (jacket) | 5.9 mm |
Tolerance outer diameter (sheath) | ± 5 % |
Material jacket | PUR |
Shore hardness jacket | 90 |
Freedom from ingredients (jacket) | CFC-free, cadmium-free, silicone-free, halogen-free, lead-free |
Material property (jacket) | matte, good machinability, abrasion-resistant, low adhesion |
Electrical data | Cable
Electrical resistance line constant wire | 26 Ω/km @ 20 °C |
---|---|
Nominal voltage AC max. | 300 V |
AC withstand voltage (wire - wire) | 2.5 kV @ 60 s |
Power frequency withstand voltage (wire - jacket) | 2.5 kV @ 60 s |
Current load capacity (standard) | to DIN VDE 0298-4 |
Current load capacity min. wire | 12 A |
Temperature range | Cable
Min. operating temperature (static) | -40 °C |
---|---|
Max. operating temperature (fixed) | 80 °C / 90 °C @ 10000 h Operation |
Operating temperature min. (dynamic) | -25 °C |
Operating temperature max. (dynamic) | 80 °C / 90 °C @ 10000 h Operation |
Operating temperature min. (drag chain) | -25 °C |
Operating temperature max. (drag chain) | 80 °C / 90 °C @ 10000 h Operation |
Resistances | Cable
Flame resistance | UL 1581 § 1090, CSA FT2, IEC 60332-2-2 |
---|---|
Oil resistance | IEC 60811-404 |
Chemical resistance | good |
Other resistances | good resistance to gasoline, resistant to hydrolysis, resistant to microbes |
Installation | Cable
Bending radius (fixed) | 5 × Outer diameter |
---|---|
Bending radius (dynamic) | 10 × Outer diameter |
No. of bending cycles (C-track) | 10 Mio. @ 25 °C |
Traversing distance (C-track) | 10 m @ 25 °C | horizontal |
Travel speed (C-track) | 3 m/s @ 25 °C |
Acceleration (C-track) | 10 m/s² @ 25 °C |
No. of torsion cycles | 2 Mio. |
Torsion stress | 180 °/m |
Torsion speed | 35 cycles/min |
Commercial data
URL Webshop | https://shop.murrelektronik.com/7000-40881-0360030 |
---|---|
GTIN | 4048879152884 |
ECLASS-6.0 | 27279218 |
ECLASS-6.1 | 27279218 |
ECLASS-7.0 | 27279218 |
ECLASS-7.1 | 27279218 |
ECLASS-8.0 | 27279218 |
ECLASS-8.1 | 27279218 |
ECLASS-9.0 | 27060312 |
ECLASS-9.1 | 27060312 |
ECLASS-10.0.1 | 27060312 |
ECLASS-10.1 | 27060312 |
ECLASS-11.0 | 27060312 |
ECLASS-11.1 | 27060312 |
ECLASS-12.0 | 27060312 |
ECLASS-13.0 | 27060312 |
ECLASS-14.0 | 27060312 |
ETIM-5.0 | EC001855 |
ETIM-6.0 | EC001855 |
ETIM-7.0 | EC001855 |
ETIM-8.0 | EC001855 |
EAN | 4048879152884 |
Accessories
---- Marking Accessories ----
---- Cable Marker ----
---- Torque Wrench ----
-
CNFP