M12 male 0° D-cod. with cable shielded
PUR 1x4xAWG22 shielded gn UL/CSA+drag ch. 1.6m
Art.No.: | 7000-14541-7960160 |
Weight: | 0.128 kg |
Country of origin: | HU |
Model designation: | MSDAL0-T796_1.6-ZS |
Technical Data
Side 1
Family construction form | M12 |
---|---|
No. of poles | 4 |
Coding | D |
Mounting method | inserted, screwed |
Thread | M12 x 1 |
Tightening torque | 0.6 Nm |
Width across flats | SW13 |
Cable outlet | straight |
Material | PUR |
Material contact | Copper alloy |
Coating contact | gold plated |
Degree of protection (EN IEC 60529) | IP67, IP66K, IP65 |
Side 2
Family construction form | free cable end |
---|---|
Stripping length (jacket) | 20 mm |
Electrical data | Supply
Operating voltage DC max. | 60 V |
---|---|
Current operating per contact max. | 1.5 A |
Industrial communication
Data transmission rate max. | 100 MBit/s |
---|---|
Transfer parameters | CAT5, Class D (ISO/IEC 11801:2002), (EN 50173-1) |
Industrial communication | Ethernet functionality
duplex | Full duplex |
---|
Installation | Connection
Mounting set | M12 x 1 |
---|
Device protection | Electrical
Additional condition protection degree | inserted, screwed |
---|---|
Pollution Degree | 3 |
Rated surge voltage | 1.5 kV |
Material group (IEC 60664-1) | I |
Mechanical data
Contour for corrugated hose | without |
---|
Mechanical data | Material data
Material screw connection | Zinc die-casting |
---|---|
Coating of fitting | nickel plated |
Locking material | Zinc die-casting |
Coating locking | Nickeled |
Mechanical data | Mounting data
Mounting method | inserted, screwed, Shaking protection |
---|
Environmental characteristics | Climatic
Operating temperature min. | -30 °C |
---|---|
Operating temperature max. | 85 °C |
Additional condition temperature range | depending on cable quality |
Important installation notes
Note on bending radius | Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces. |
---|---|
Note on strain relief | Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties. |
Conformity
Product standard | DIN EN 61076-2-101 (M12) |
---|
Cable data
General data | Cable
Cable identification | 796 |
---|
Structure | Cable
Amount stranding | 1 |
---|---|
Stranding | 4 wires stranded |
Cable shielding (type) | copper braid, tinned |
Cable shielding (coverage) | 85 % |
Banding | Fleece, Foil |
Filler | yes |
Wire arrangement | white, yellow, blue, orange |
Mechanical data | Cable
Cable weigth | 69.3 g/m |
---|---|
Material wire insulation | PE |
Amount wires | 4 |
Outer diameter insulation | 1.4 mm |
Outer diameter tolerance core insulation | ± 0.05 mm |
Shore hardness wire insulation | 65 ± 2 Shore D |
Ingredient freeness wire insulation | CFC-free, halogen-free, lead-free |
Amount strands (wire) | 7 |
Diameter of single wires | 30 AWG |
Conductor crosssection (wire) | 22 AWG |
Material conductor wire | Stranded copper wire, bare |
Outer-diameter (jacket) | 6.7 mm |
Tolerance outer diameter (sheath) | ± 5 % |
Material jacket | PUR |
Shore hardness jacket | 89 ± 2 Shore D |
Freedom from ingredients (jacket) | CFC-free, cadmium-free, silicone-free, halogen-free, lead-free |
Material property (jacket) | matte, good machinability, abrasion-resistant, low adhesion |
Material inner jacket | FRNC |
Color (inner jacket) | natural |
Electrical data | Cable
Electrical resistance line constant wire | 55 Ω/km @ 20 °C |
---|---|
Electrical capacity line constant (wire - wire) | 50,000 pF/km |
Isolation resistance | 5,000 MΩ × km |
Nominal voltage AC max. | 300 V |
AC withstand voltage (wire - wire) | 2 kV @ 60 s |
Power frequency withstand voltage (wire - jacket) | 2 kV @ 60 s |
AC withstand voltage (wire - shield) | 2 kV @ 60 s |
Current load capacity (standard) | to DIN VDE 0298-4 |
Current load capacity min. wire | 4.8 A |
Characteristic impedance | 100 Ω ± 15 % |
Temperature range | Cable
Min. operating temperature (static) | -40 °C |
---|---|
Max. operating temperature (fixed) | 80 °C / 9999 h Operation |
Operating temperature min. (dynamic) | -30 °C |
Operating temperature max. (dynamic) | 70 °C |
Operating temperature min. (drag chain) | -30 °C |
Operating temperature max. (drag chain) | 70 °C |
Resistances | Cable
Flame resistance | UL 1581 § 1090, UL 1581 § 1100, IEC 60332-1-2 |
---|---|
Oil resistance | IEC 60811-404, IRM 901 |
Ozone resistance | IEC 60811-403 |
UV resistance | UL 1581§1200 |
Other resistances | resistant to hydrolysis, resistant to microbes, MUD-resistant (NEK 606) |
Installation | Cable
Bending radius (fixed) | 5 × Outer diameter |
---|---|
Bending radius (dynamic) | 12 × Outer diameter |
No. of bending cycles (C-track) | 3 Mio. @ 25 °C |
Traversing distance (C-track) | 5 m @ 25 °C |
Travel speed (C-track) | 3.3 m/s @ 25 °C |
Acceleration (C-track) | 2 m/s² @ 25 °C |
No. of torsion cycles | 1 Mio. @ 25 °C |
Torsion stress | 180 °/m |
Torsion speed | 35 cycles/min |
Commercial data
URL Webshop | https://shop.murrelektronik.com/7000-14541-7960160 |
---|---|
EAN | 4065909006511 |