MVK Fusion
MVK PN FDI6/3 FDO2/1 DIO4 IOL2 IRT PP
Art.No.: | 55510 |
Weight: | 1.4 kg |
Country of origin: | DE |
Model designation: | MVK PN FDI6/3 FDO2/1 DIO4 IOL2 IRT PP |
Description
One module for maximum variety
The special thing about MVK Fusion is its diversity. The PROFINET/PROFIsafe module combines three elementary functions of installation technology – digital standard sensors and actuators, digital safety-related sensors and actuators and IO-Link.
With MVK Fusion, fewer fieldbus modules are required per modular unit, in the best case just one. This offers attractive opportunities for a wide range of automation applications.
Further information on MVK Fusion can be found at Fieldbus module MVK Fusion.
Connection cables are in the online shop under "Connection Technology".






Technical Data
Safety codes
Service life | 20 a |
---|---|
Category (EN ISO 13849-1) | 4 (X0, X1, X2, X3); 3 (X7 PIN 3) |
PFHd (IEC 61508) | 7,8 E-10/h |
PFHd (IEC 62061) | 48 E-10/h |
Performance level (EN ISO 13849-1) | e (X0, X1, X2, X3); d (X7 PIN 3) |
SIL (IEC 61508) | 3 (X0, X1, X2, X3); 2 (X7 PIN 3) |
SIL CL (IEC 62061) | 3 |
Electrical data | Supply
Norm operating voltage | EN 61131-2 |
---|---|
Operating voltage US DC | 24 V |
Operating voltage UA DC | 24 V |
Total current US max. | 16 A |
Electrical data | Input
Type input | PNP, for 3-wire sensors or mechanical switches, IO-Link Devices |
---|---|
Number of F inputs | 6 |
Overload resistant | yes |
Short-circuit protected | yes |
Type Safety input | for electronical sensors or mechanical switches |
Sensor current US per input max. | 0,7 A |
Current carrying capacity max. | 0,7 A |
Electrical data | Output
Switching behavior safety output | 2 FDO X3 (PIN 2, PIN 4: pp, pm, ppm switching); 1 FDO X7 (PIN 2: pp switching) |
---|---|
Overload resistant | yes |
Short-circuit protected | yes |
Output current per pin (safety) max. | 2 A |
Output current per pin max. | 2 A |
Total current outputs max. | 8 A |
Industrial communication
Supported protocol | PROFINET |
---|
Industrial communication | Profinet
Number of active connections (IO controller) max. | 2 |
---|---|
IRT (network communication) | yes |
MRP client | yes |
PROFINET Netload Class | III |
PROFINET addressing | DCP |
PROFINET conformance class | C |
PROFINET specification | V2.3 |
Shared device/input | yes |
Industrial communication | IO-Link
IO-Link type | 2× Master |
---|---|
Port Class | A, B |
IO-Link revision ID | V1.1.2 |
IO-Link transmission rate | COM1, COM2, COM3 |
IO-Link process data length input | 32 Bytes |
IO-Link process data length output | 32 Bytes |
Automatic baudrate detection | yes |
Diagnostics
Actuator warning | per channel via LED and BUS |
---|---|
Diagnostic via BUS | per module and channel |
Diagnostic via LED | per module and channel |
Wire break detection | yes |
IO-Link events | No voltage, Undervoltage supply |
Short circuit diagnosis | yes |
LED display | Ethernet connection/data traffic |
Cross-link detection | Sensor/Actuator |
Overload diagnosis | yes |
Device protection | Electrical
Degree of protection (EN IEC 60529) | IP67 |
---|---|
Galvanic separation (operating voltage) | yes |
Mechanical data | Mounting data
Suitable for mounting type | 2-hole screw mounting |
---|---|
Height | 51,2 mm |
Width | 63 mm |
Depth | 225 mm |
Environmental characteristics | Climatic
Operating temperature min. | -20 °C |
---|---|
Operating temperature max. | 60 °C |
Storage temperature min. | -40 °C |
Storage temperature max. | 85 °C |
Connection data
Connection types
Connection type 1 | X0-X2 |
---|---|
Connection type 2 | X3 |
Connection type 3 | X4, X5 |
Connection type 4 | X6 |
Connection type 5 | X7 |
Connection type 6 | XD1, XD2 |
Connection type 7 | XF1, XF2 |
Connection type 1
Family construction form | M12 |
---|---|
Gender | female |
Color contact carrier | yellow |
Coding | A |
No. of poles | 5 |
PIN 1 | 24 V DC (US 1) Test Pulse P 4 |
PIN 2 | FDI |
PIN 3 | 0 V (US 1) |
PIN 4 | FDI |
PIN 5 | 24 V DC (US 1) Test Pulse P 2 |
Connection type 2
Family construction form | M12 |
---|---|
Gender | female |
Color contact carrier | yellow |
Coding | A |
No. of poles | 5 |
PIN 1 | n.c. |
PIN 2 | FDO |
PIN 3 | 0 V (US 2) |
PIN 4 | FDO |
PIN 5 | n.c. |
Connection type 3
Family construction form | M12 |
---|---|
Gender | female |
Color contact carrier | black |
Coding | A |
No. of poles | 5 |
PIN 1 | 24 V DC (US 2) |
PIN 2 | DI / DO |
PIN 3 | 0 V (US 2) |
PIN 4 | DI / DO |
PIN 5 | PE |
Connection type 4
Family construction form | M12 |
---|---|
Gender | female |
Color contact carrier | gray |
Coding | A |
No. of poles | 5 |
PIN 1 | 24 V DC (US 1) |
PIN 2 | DI |
PIN 3 | 0 V (US 1) |
PIN 4 | DI / IO-Link |
PIN 5 | n.c. |
Connection type 5
Family construction form | M12 |
---|---|
Gender | female |
Color contact carrier | gray |
Coding | A |
No. of poles | 5 |
PIN 1 | 24 V DC (US 1) |
PIN 2 | DO (US 2) |
PIN 3 | 0 V (US 1) |
PIN 4 | DI / IO-Link |
PIN 5 | 0 V (US 2) |
Connection type 6
Family construction form | Push Pull |
---|---|
Gender | male |
Color contact carrier | green |
No. of poles | 5 |
PIN 1 | 24 V DC (US 1) |
PIN 2 | 0 V (US 1) |
PIN 3 | 24 V DC (US 2) |
PIN 4 | 0 V (US 2) |
PIN 5 | PE |
Connection type 7
Family construction form | RJ45 |
---|---|
Gender | female |
Color contact carrier | black |
No. of poles | 8 |
PIN 1 | TD + |
PIN 2 | TD - |
PIN 3 | RD + |
PIN 4 | n.c. |
PIN 5 | n.c. |
PIN 6 | RD - |
PIN 7 | n.c. |
PIN 8 | n.c. |
Commercial data
ECLASS-6.1 | 27242604 |
---|---|
ECLASS-7.0 | 27242604 |
ECLASS-8.0 | 27242604 |
ECLASS-9.0 | 27242604 |
ECLASS-10.1 | 27242604 |
ECLASS-11.1 | 27242604 |
ECLASS-12.0 | 27242604 |
customs tariff number | 85389099 |
GTIN | 4048879714983 |
Packaging unit | 1 |
Accessories
---- Emergency Stop Button ----
---- Button ----
---- Sensor-Actuator Adapter ----
---- Power-Cable ----
---- Heat Sink ----
---- Screw Plug ----
---- Device Marker ----
---- Sonsor-Actuator-Cable ----
---- Digital I/O Module ----